{"id":2020,"date":"2026-10-06T14:53:14","date_gmt":"2026-10-06T12:53:14","guid":{"rendered":"https:\/\/www.hsu-hh.de\/emt\/?page_id=2020"},"modified":"2026-10-06T14:56:23","modified_gmt":"2026-10-06T12:56:23","slug":"drahtlos-integrierte-sensor-und-kommunikationssystemefuer-industrielle-anwendungen","status":"publish","type":"page","link":"https:\/\/www.hsu-hh.de\/emt\/forschungsthemen\/drahtlos-integrierte-sensor-und-kommunikationssystemefuer-industrielle-anwendungen","title":{"rendered":"Drahtlos integrierte Sensor- und Kommunikationssystemef\u00fcr industrielle Anwendungen"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"559\" src=\"https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/IOLW_Factory-1024x559.jpg\" data-credit=\"EMT\" alt=\"IO-Link Wireless Baugruppe f\u00fcr industrielle Sensor-Aktor-Kommunikation\" class=\"wp-image-1563\" srcset=\"https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/IOLW_Factory-1024x559.jpg 1024w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/IOLW_Factory-300x164.jpg 300w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/IOLW_Factory-768x419.jpg 768w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/IOLW_Factory-1536x838.jpg 1536w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/IOLW_Factory-2048x1117.jpg 2048w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/IOLW_Factory-1100x600.jpg 1100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-red-color has-text-color has-link-color wp-elements-66068ff0059643f36dae9644b0163c2a\">IO-Link Wireless (IEC 61139-3)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Weltweit standardisierte Funktechnologie (IEC 61139-3) f\u00fcr die schnelle, hochzuverl\u00e4ssige und deterministische Sensor-Aktor-Kommunikation in Fertigungszellen mit Zykluszeiten unter 5 ms und einer Paketfehlerrate unter 10\u207b\u2079.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.hsu-hh.de\/emt\/io-link-wireless-de\" data-type=\"page\" data-id=\"265\">Mehr zu IO-Link Wireless und Normung erfahren \u2192<\/a><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/5G_Campus_HSU_Telekom-1024x683.jpg\" data-credit=\"EMT\" alt=\"Echtzeit-Koexistenzmanagement und Breitband-Funkkanalmesstechnik im 2,4-GHz-Band\" class=\"wp-image-1562\" srcset=\"https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/5G_Campus_HSU_Telekom-1024x683.jpg 1024w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/5G_Campus_HSU_Telekom-300x200.jpg 300w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/5G_Campus_HSU_Telekom-768x512.jpg 768w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/5G_Campus_HSU_Telekom-1536x1025.jpg 1536w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/5G_Campus_HSU_Telekom-2048x1366.jpg 2048w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/5G_Campus_HSU_Telekom-1100x734.jpg 1100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-red-color has-text-color has-link-color wp-elements-63996d8b6d66638b30061e852410d354\">Wireless Industrial IoT (WIIoT)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Echtzeitf\u00e4hige Funksysteme und dynamisches Koexistenzmanagement im 2,45-GHz- und 5-GHz-Band f\u00fcr metallisch hochreflektierende Industrieumgebungen sowie energieautarke Sensorsysteme mit Energy Harvesting.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.hsu-hh.de\/emt\/wireless-automation-3\" data-type=\"link\" data-id=\"https:\/\/www.hsu-hh.de\/emt\/wireless-automation-3\">Mehr zu Wireless Industrial IoT erfahren \u2192<\/a><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\" \/>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/MessungFraunhofer_20251210_1-1024x768.png\" data-credit=\"HSU\/EMT\" alt=\"\" class=\"wp-image-1672\" srcset=\"https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/MessungFraunhofer_20251210_1-1024x768.png 1024w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/MessungFraunhofer_20251210_1-300x225.png 300w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/MessungFraunhofer_20251210_1-768x576.png 768w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/MessungFraunhofer_20251210_1-1536x1152.png 1536w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/MessungFraunhofer_20251210_1-2048x1536.png 2048w, https:\/\/www.hsu-hh.de\/emt\/wp-content\/uploads\/sites\/686\/2026\/08\/MessungFraunhofer_20251210_1-1100x825.png 1100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading has-red-color has-text-color has-link-color wp-elements-ee894f80aba5d55b224db9c531a59fb5\">Echt-Zeit f\u00e4higes drahtloses Sensor Netzwerk zur Form- und Dehnungsmessung f\u00fcr Gro\u00dfstrukturen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Drahtlose Sensornetzwerk erm\u00f6glicht die skalierbare Echtzeit-Erfassung von Form, Verformung und lokaler Dehnung gro\u00dffl\u00e4chiger Bauteile.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.hsu-hh.de\/emt\/echt-zeit-faehiges-drahtloses-sensor-netzwerk-zur-form-und-dehnungsmessung-fuer-grossstrukturen\" data-type=\"page\" data-id=\"1667\">Mehr zu drahtlosem Sensor Netzwerk erfahren \u2192<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>IO-Link Wireless (IEC 61139-3) Weltweit standardisierte Funktechnologie (IEC 61139-3) f\u00fcr die schnelle, hochzuverl\u00e4ssige und deterministische Sensor-Aktor-Kommunikation in Fertigungszellen mit Zykluszeiten unter 5 ms und einer Paketfehlerrate unter 10\u207b\u2079. Mehr zu [&hellip;]<\/p>\n","protected":false},"author":62,"featured_media":0,"parent":1551,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":["post-2020","page","type-page","status-publish","hentry","category-forschung"],"lang":"de","translations":{"de":2020},"pll_sync_post":{},"_links":{"self":[{"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/pages\/2020","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/users\/62"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/comments?post=2020"}],"version-history":[{"count":6,"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/pages\/2020\/revisions"}],"predecessor-version":[{"id":2071,"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/pages\/2020\/revisions\/2071"}],"up":[{"embeddable":true,"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/pages\/1551"}],"wp:attachment":[{"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/media?parent=2020"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/categories?post=2020"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hsu-hh.de\/emt\/wp-json\/wp\/v2\/tags?post=2020"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}