{"id":1597,"date":"2020-12-04T11:40:24","date_gmt":"2020-12-04T10:40:24","guid":{"rendered":"https:\/\/www.hsu-hh.de\/ema\/?page_id=1597"},"modified":"2021-01-04T07:57:12","modified_gmt":"2021-01-04T06:57:12","slug":"laboratory-equipment-2","status":"publish","type":"page","link":"https:\/\/www.hsu-hh.de\/ema\/en\/laboratory-equipment-2","title":{"rendered":"Laboratory equipment"},"content":{"rendered":"\n<p><strong>Laboratory of the Chair of Electrical Machines and Drive Systems<\/strong><\/p>\n\n\n\n<p>The electric machine laboratory consists of a workshop with a 5t assembly crane. Via a driveway and floor hatches, devices with large dimensions and weights can be transported into the hall. In the laboratory, 12 clamping plates for experimental setups are available.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"593\" height=\"612\" src=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_001.png\" data-credit=\"EMA\" alt=\"\u00dcbersichtsbild mit Arbeitspl\u00e4tzen\" class=\"wp-image-1144\" srcset=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_001.png 593w, https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_001-291x300.png 291w\" sizes=\"auto, (max-width: 593px) 100vw, 593px\" \/><\/figure>\n\n\n\n<p>Illustrations of the laboratory: Overview image with workstations (top left), power supply (top right), test setup (center left), <br>crossbar distributor (center right), stress analysis workstation 9 (bottom left), test setup for machine characterization (bottom right)<\/p>\n\n\n\n<p>The power supply of the test stands is provided by rotating converters located in the basement and a three-phase power supply per workstation. The distribution to the test benches is done via a crossbar distributor. Furthermore, a number of static converters are available for the test benches.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Rotating converters:<\/h4>\n\n\n\n<ul class=\"wp-block-list\"><li>3 Phase power supply, rating 3 x 63A<\/li><li>3 phase variable transformer 0 \u2013 500V, 50kVA<\/li><li>DC 0 \u2013 440V, 50kW<\/li><li>Frequency converter 100 \u2013 500Hz, 20 \u2013 500V, rating app. 50kVA<\/li><li>Frequency converter 15 \u2013 100Hz, 20-500V, rating appr. 50kVA<\/li><\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Static converters:<\/h4>\n\n\n\n<ul class=\"wp-block-list\"><li>Bidirectional 3-phase power supply 10 &#8211; 1000Hz<\/li><li>DC power supply 0 \u2013 500V, 0 \u2013 600A up to 40kW<\/li><li>3 phase power supply 45 -5000 Hz, 15kVA<\/li><li>3 phase power supply realized by a linear amplifier 0 \u2013 30kHz, up to 15kVA<\/li><li>Several electronic loads for DC<\/li><li>4-Quadrant linear amplifier (Hubert), 250W, 2 channels 0 \u2013 1MHz<\/li><\/ul>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"562\" height=\"257\" src=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_002.png\" data-credit=\"EMA\" alt=\"Statische Umformer\" class=\"wp-image-1138\" srcset=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_002.png 562w, https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_002-300x137.png 300w\" sizes=\"auto, (max-width: 562px) 100vw, 562px\" \/><\/figure>\n\n\n\n<p>The image shows static converter, linear amplifiers by Spitzenbergerg &amp; Spie\u00df , Heiden Power and ELGAR as well as DC-<br>power-sources and sinks<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Measurement Equipment:<\/h4>\n\n\n\n<ul class=\"wp-block-list\"><li>Power Meter Yokogawa WT1800 ( up to 6 channels)<\/li><li>Power Meter Norma 4000, 6000<\/li><li>Torque measuring flange HBM 2 -500Nm for several rotational speed ranges<\/li><li>Function generators (Tektronix and HP)<\/li><li>Mixed Signal Oscilloscopes<\/li><li>Data Recorder by HBM<\/li><li>SLM SCADAS Mobile<\/li><li>Dynamic signal analyzer HP 3562A<\/li><li>Teslameter<\/li><li>Thermocamera<\/li><\/ul>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"598\" height=\"267\" src=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_003.png\" data-credit=\"EMA\" alt=\"Messequipment im EMALabor\" class=\"wp-image-1139\" srcset=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_003.png 598w, https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_003-300x134.png 300w\" sizes=\"auto, (max-width: 598px) 100vw, 598px\" \/><\/figure>\n\n\n\n<p>The image shows several measurement devices (power meter oscilloscopes, signal analyzer, RMS<br>multimeters).<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Testbenches:<\/h4>\n\n\n\n<ul class=\"wp-block-list\"><li>ETA4000 up to 10.000 rpm, 4kW, vector control load machine<\/li><li>Chassis dynamometer for Ranger vehicle<\/li><li>Test bench for super conductors (cyro pump for 40W of power loss, vacuum chamber ( up to 3&#215;10-2 mbar<\/li><li>Several pendulum machines for torque measurement<\/li><li>High speed test bench for machines up to 50.000rpm, Magtrol eddy current brake<\/li><li>Modal analysis system Siemens LMS Scadas using 24 piezo PCB triaxial sensors<\/li><li>Balancing machine<\/li><li>Universal test bench (Testometric) for measuring forces up to 10kN, tensile, compressing and flexural test<\/li><\/ul>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"585\" height=\"312\" src=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_004.png\" data-credit=\"EMA\" alt=\"Bilder von Versuchsst\u00e4nden im EMA Labor\" class=\"wp-image-1137\" srcset=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_004.png 585w, https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_004-300x160.png 300w\" sizes=\"auto, (max-width: 585px) 100vw, 585px\" \/><\/figure>\n\n\n\n<p>The image shows the balancing machine ETA4000, chassis dynamometer, eddy current brake, servo motor with HBM torque sensor<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">IT-equipment:<\/h4>\n\n\n\n<ul class=\"wp-block-list\"><li>dSPACE HIL Systeme, SCALEXIO, DS1005<\/li><li>Simulation workstations, 40 cores, 1TB RAM, Nvidia Tesla V100<\/li><\/ul>\n\n\n\n<p><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"528\" height=\"164\" src=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_005.png\" data-credit=\"EMA\" alt=\"SCALECIO Labbox\" class=\"wp-image-1142\" srcset=\"https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_005.png 528w, https:\/\/www.hsu-hh.de\/ema\/wp-content\/uploads\/sites\/588\/2019\/11\/Image_005-300x93.png 300w\" sizes=\"auto, (max-width: 528px) 100vw, 528px\" \/><\/figure>\n\n\n\n<p>The image shows dSpace SCALEXIO systems (left), dSpace DS1005 (center), National Instruments PXI Box (right)<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Simulation Software:<\/h4>\n\n\n\n<ul class=\"wp-block-list\"><li>Malab, Simulink, Toolboxen<\/li><li>FEM ANSYS Workbench, academic research Maxwell 2D\/3D, RMxprt ANSYS STRUKTURS, ANSYS FLUIDS, ANSYS ELECTRONIKS<\/li><li>PSS SINCAL \/ Netomac<\/li><li>LMS Test Lab<\/li><li>Labview<\/li><li>dSPACE ControlDesk<\/li><li>Solidworks academic research<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Laboratory of the Chair of Electrical Machines and Drive Systems The electric machine laboratory consists of a workshop with a 5t assembly crane. Via a driveway and floor hatches, devices [&hellip;]<\/p>\n","protected":false},"author":53,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"categories":[7],"tags":[],"class_list":["post-1597","page","type-page","status-publish","hentry","category-research"],"_links":{"self":[{"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/pages\/1597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/users\/53"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/comments?post=1597"}],"version-history":[{"count":15,"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/pages\/1597\/revisions"}],"predecessor-version":[{"id":1696,"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/pages\/1597\/revisions\/1696"}],"wp:attachment":[{"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/media?parent=1597"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/categories?post=1597"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hsu-hh.de\/ema\/wp-json\/wp\/v2\/tags?post=1597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}